PDF・Wordの本文は中国語で、英語の要旨を含みます。
要旨
本研究では、資料で確認した設計条件とパラメトリック解析の仮定を区別しています。計算結果は実機検証に代わるものではありません。以下の英語要旨に結果と適用限界を示します。
This study evaluates a column-mounted manipulator with a rated working load of 500 kg at the existing 2.5 m end-joint radius and a hypothetical 3.5 m extension. Drawing geometry for eight M24 L-shaped cast-in anchors is separated from resistance evidence. A complete load path includes the payload, fixture, arm, counterweight and fixed column. Tension-only anchor springs and compression-only contact are solved with exact polygon integration. Unverified masses, centres of gravity and accelerations are explicit research inputs. Under the representative combined case, overturning moments are 25.39 and 34.83 kN m, and peak individual anchor tensions are 9.65 and 14.11 kN. For the suggested 1.5 by 1.5 by 0.8 m footing, peak soil pressures are 113.4 and 214.7 kPa, with contact fractions of 66.2% and 34.0%. The 3.5 m pressure maximum occurs near 24 degrees rather than necessarily along an edge or diagonal. Steel, plate bending, concrete anchorage, footing structure and ground bearing are assessed separately. Thirty-four numerical verification checks support the calculation implementation. The conditional results do not certify the actual equipment, anchorage or foundation, and do not authorize extending the existing machine to 3.5 m.
Keywords: column-mounted manipulator; overturning moment; anchor group; unilateral contact; eccentric footing pressure; parametric study
中国語の全文
PDF・Wordの本文は中国語で、英語の要旨を含みます。