RESEARCH REPORT · Technical Research AUREK-RC-AR-039

Fail-Safe Design and Fault-Injection Verification for Power-Battery-Pack Handling Tooling

For heavy battery-pack grippers, this study proposes an architecture based on geometric support, self-holding locks, supported-load release, multi-signal diagnostics, and safe recovery, with a fault-injection matrix, FMEA, and evidence-chain requirements.

Key points of this article
  • Heavy-duty battery packs should use geometric support and mechanical self-retention as the main load-bearing paths.
  • The target state after a fault is to maintain the load, stop dangerous actions, prohibit release and allow safe recovery.
  • Fault injection needs to cover pressure, valves, latches, sensors, communications, mismatches and false release commands.
  • Testing should proceed from simulated and substitute loads to real battery packs step by step, with all evidence traceable.
Judgment rules:Documentation Properties: Methodology Study and Validation Scheme. This article does not perform fault injection for a specific battery pack fixture, nor does it provide a certificate of conformity; sample loads and response requirements must be confirmed by project risk assessment, real load testing and customer technical conditions.

00executive summary

EV battery packs have high mass, complex center-of-gravity distributions, and sensitive housings and sealing surfaces, and may present risks associated with high-voltage connections, cooling interfaces, and damaged cells. If handling tooling loses air or electrical power, fails to lock completely, receives invalid sensor signals, or releases inadvertently, the consequences can include not only a dropped workpiece but also housing deformation, damage to insulation or cooling systems, and subsequent safety hazards. GB 38031-2025 took effect on 2026-7-1 and specifies safety requirements for traction batteries used in electric vehicles [1]. The standard addresses battery-product safety and does not directly replace mechanical-safety design of handling tooling, but it demonstrates that battery packs require rigorous prevention of mechanical damage and abnormal energy events.

This study proposes a fail-safe architecture based on priority for geometric support, control of hazardous release, diagnosability of single faults, and safe controlled set-down under abnormal conditions. The tooling shall not rely primarily on friction or continuous pneumatic pressure to retain a heavy load. Priority shall be given to a clear mechanical load path, self-retaining locks after closure, an interlock that permits release only after support is confirmed, and diverse-signal diagnostics for pressure, position, locking, and load state. Safety-related control functions may be designed in accordance with ISO 13849-1:2023 and validated by analysis and testing in accordance with ISO 13849-2:2012 [2][3]; the required performance level is determined by the project-specific risk assessment.

Core conclusion

  • Heavy battery packs shall use geometric support and mechanically self-retaining features as the primary load path; a single pneumatic-pressure, vacuum, or friction function shall not be the sole drop-prevention measure.
  • "Failsafe" does not mean continuing production after all failures, but maintaining load after failure, stopping dangerous actions, prohibiting release, and entering a diagnosable recovery state.
  • Fault injection must cover stuck sensors, signal shorts/opens, stuck valves, ruptured pipes, pressure drops, communications outages, recipe mismatches and false release commands.
  • The testing should follow the progressive principles from low energy to high energy, alternative loads to real battery packs, and single faults to reasonable combinations of faults.
  • Verification evidence must be traceable to safety requirements, fault assumptions, test steps, original signals, judgment and rectification closed loops.

01Research scope and safety objectives

The study covers purpose-built handling tooling for battery modules, lower housings, battery trays, and complete power-battery packs during assembly, inspection, rework, and line-side transfer. The carrier may be a Pneumatic Industrial Manipulator, lifting device, robot, or purpose-built machine. This report focuses on the tooling and control interface; it excludes cell electrochemical design, BMS algorithm certification, and transport regulations.

The safety objectives fall into four categories: protect personnel from dropped-load and crushing hazards; prevent handling damage to the battery-pack housing, sealing surfaces, or interfaces beyond product limits; prevent a single tooling fault from directly causing hazardous release; and provide defined steps for transferring the load to safe support during an abnormal condition. ISO 12100 requires hazard identification and risk reduction throughout the machinery life cycle [4], while ISO/TR 20218-1 provides safety guidance for the design and integration of robot end effectors [5].

01 Research scope and safety objectives — data table
Safety FunctionTrigger conditiontarget responseEvidence that must be retained
Clamping/supporting confirmationBefore pickupLifting is prohibited without confirmationPosition, pressure/force, locked status
load holdingLoss of air supply, loss of electrical power, valve failureNo dangerous release, stop movementMaintain time, displacement, structural state
support-confirmed releaseworkpiece is in position and the orientation is allowedOnly allowed to unlock/unclampSupport signal, position, and command record
mismatch suppressionBattery model/tooling/recipe is inconsistentNo clamping or lifting allowedID, recipe version, interlocking log
Exception recoveryAny safety related failureEnter the controlled set-down or maintenance stateRecovery steps and authorization records

02Bearer architecture and fail-safe principles

02.1 Priority for Geometric Support

The battery pack has a large mass and usually has a structural allowable zone and a no-touch zone at the bottom. Prioritize the use of supporting arms, fork supports, load-bearing holes/side beam positioning, or mechanical grab points confirmed by the product side to allow gravity to be transmitted through a clear structural path. The cylinder or motor is mainly used for closing, positioning and locking, and should not lose all load immediately after the energy disappears.

If clamping friction force transmission must be used, verifiable data on the minimum friction coefficient, contact material, surface condition and clamping force should be obtained, and the effect of clamping on the housing, cooling plate, sealing surface and coating should be evaluated. For heavy-duty safety functions, geometric support is often more robust than simply increasing the clamping force.

02.2 Load Cases and Example Calculations

F_eq = m · (g + a_z) + F_shock F_design = S_L · F_eq

Assume a battery pack mass of 650 kg and a maximum upward acceleration of 0.25g, with no additional impact load. The equivalent vertical load is approximately 7.97 kN. With the example safety factor S_L=2.0, the design vertical load is approximately 15.9 kN; four ideal, uniformly loaded support points carry approximately 4.0 kN per point on average. The actual design must also account for center-of-gravity offset, unequal support stiffness, manufacturing tolerances, inclination, braking, and failure of one support point. This example is neither a project load rating nor a recommended safety factor.

For eccentric centers of gravity, each fulcrum reaction should be calculated through static equilibrium or finite elements. The total load cannot be simply distributed evenly. If the battery pack has different lengths, masses or accessory configurations, the "maximum single point reaction force" rather than the "maximum total mass" should be used as one of the fulcrum design inputs.

02.3 Locking and releasing

After closing, the locking mechanism shall provide a verifiable mechanical state. If drive energy is lost, it shall retain the load or at least prevent hazardous release. Release requires confirmation that the workpiece is supported, the tooling is at a permitted position, motion has stopped, the personnel zone is safe, and the operating command is valid. Any sensor conflict shall lead to a conservative state rather than substitution of a software default for actual feedback.

03Pneumatic, electrical and control safety architecture

ISO 4414:2010 applies to pneumatic systems and components on machinery and addresses significant hazards associated with their intended use [6]. For battery-pack tooling, the pneumatic design shall address line rupture, fitting disconnection, valve-spool seizure, supply-pressure fluctuation, residual energy, and maintenance isolation. Air receivers or pressure-retention devices can only delay loss of capacity; they do not automatically constitute safe load holding.

Recommended diagnostic layers include source pressure; both actuator chambers or other critical-circuit pressures; lock position; gripper-jaw/support-arm position; workpiece presence; supported state; load/weight plausibility; and control-communication health. Signals should be physically diverse wherever practicable so that two nominally redundant signals do not actually depend on the same mechanical target or cable.

Lift_Enable = Load_Present ∧ Clamp_Closed ∧ Lock_Confirmed ∧ Pressure_OK ∧ Recipe_Match Release_Enable = Supported ∧ Safe_Position ∧ Motion_Stopped ∧ Operator_Command ∧ Diagnostics_OK

Logical expressions only describe functional relationships and are not equivalent to meeting a certain performance level. The structure, diagnostic coverage, common cause failures, software and verification of safety-related control systems should be implemented according to project selection standards [2][3].

04Hazard Analysis and FMEA

04 Hazard Analysis and FMEA — data table
failure modelocal causespotential consequencesdesign controlVerification method
Sudden loss of the main air supplyLoss of air in the main header or a disconnected fittingClamping force decreases and load slipsMechanical support, self-retaining lock, check valve, and monitoringloss of compressed air fault injection
Single branch ruptureWorn hoses and damaged jointsSingle gripper jaw failure, uneven loadZone isolation, support-point redundancy, and pressure monitoringIntroduce a leak at the specified location
The valve core is stuck in the release positionContamination, mechanical failureInadvertent unclampingRelease isolation, biconditional permission, mechanical retentionSimulated valve stuck
The lock is not fully in placeTolerances, foreign matter, misalignmentDisconnection while carrying the loadIndependent locking feedback, geometric anti-offSemi-locked state test
Sensor stuck openLine short circuit, software freezeNot clamped but allowed to liftComplementary signals and timing/plausibility diagnosticsSignal is forced to 1
Sensor stuck closedOpen circuit, target deviationUnable to release or misjudgment of faultOpen-circuit diagnostics and maintenance stateSignal is forced to 0
Model recipe errorBarcode-reading, network, or operator errorWrong stress point and interferenceMechanical error-proofing, ID consistency, version controlmismatch injection
Release command by mistakeHuman-machine interface or program errorDropped suspended loadSupport-confirmation interlock, restricted position, dual actionIssue release command while hanging in the air
Communication interruptionBus failure, PLC restartStatus unknownKeep load, stop movement, prohibit releaseDisconnect/restart injection
Abnormal loadDouble bags, foreign objects, abnormal center of gravityOverloading of structure or lifting gearReasonable weight, pick-up position to prevent double pick-upSurrogate-load testing

FMEA shall be used together with a fault tree or safety-requirements matrix. For the load-drop top event, identify minimal cut sets such as “no geometric support + lock failure + erroneous release command” or “common-cause sensor failure + no software diagnosis.” If any single fault can trigger the top event, modify the structure first rather than merely lowering the occurrence rating.

05Fault injection verification strategy

ISO 13849-2:2012 specifies procedures and conditions for verification of safety functions, implementation categories and performance levels through analysis and testing [3]. Fault injection is part of verification and is not a substitute for complete design review, component data, calculations, and software verification. A risk assessment, test area isolation, alternative load design, emergency support and recovery plans must be completed prior to testing.

05.1 Grading order

  1. Model and Logic Level: Force inputs, acknowledge state machines and alarms in control simulation or offline logic.
  2. Low energy bench level: Use empty fixtures or lightweight dummies to inject wire breaks, short circuits, valve and pressure failures.
  3. Rated alternative load level: Verify retention, displacement and structure using geometrically and mass equivalent non-battery loads.
  4. Real battery pack level: Only interface and product protection items that cannot be covered by the first three levels are tested. The risks are controlled and authorized.
  5. Field integration level: Confirm interlocking with manipulator, lifting devices, conveyor lines, tooling and safety systems.

05.2 Fault injection matrix

05.2 Fault injection matrix — data table
No.Inject faultinject momentexpected system statekey record
FI-01Shut off the main air supplyResting after lifting/movingKeep the load, stop dangerous movements, and prohibit releasePressure, displacement, stop time
FI-02Rapid leakage in a single branchThe most unfavorable postureIsolate the fault, issue an alarm, and maintain a condition that permits controlled set-downZone pressure, fulcrum reaction force
FI-03Lock-position feedback stuck openbefore closingLifting is not permittedInput/output and alarm log
FI-04Lock-position feedback stuck closedhalf locked statePlausibility diagnostic is triggered; lifting is not permittedPosition, pressure, signal contradictions
FI-05Release-valve command stuck activefloating statePhysical or control layers prevent hazardous releasesValve current, pressure, lock status
FI-06False support-confirmation signalNot in placeDouble/diversity check rejects releaseSupport, position, load changes
FI-07Controller restart/bus lostIn transitThe output enters the defined safe state and the load remainsRestart time, output status
FI-08Incorrect battery model / recipeBefore pickupThe recipe is inconsistent and the action is prohibitedID, recipe version, CRC/signature
FI-09emergency stopmaximum reasonable speedStop without releasing the loadPeak acceleration, structure/load displacement
FI-10Maintenance release misoperationunsupportedSubject to permissions and mechanical conditionsPermissions, steps, lock status

Each test case shall define three outcomes: pass, fail, and engineering review required. Do not record only whether the load ultimately dropped; also check peak displacement, changes in lock state, alarm visibility, whether recovery requires bypassing a safety function, and whether the battery pack sustained hidden damage.

06Acceptance indicators and evidence chain

Project metrics shall be derived from the risk assessment and technical agreement. Common categories include rated and worst-case loads, reaction at a single support point, permitted housing deformation, holding time, maximum slip, stopping acceleration, fault-detection time, alarm and reset, release permission, and maintenance isolation. This report gives no universal values for these metrics because battery packs, carriers, and personnel exposure conditions differ substantially.

06 Acceptance indicators and evidence chain — data table
evidence layerTypical documentsQuality requirements
requirementsSafety Requirements Specification, customer interfaces, product prohibited/restricted zonesUnique number, version and source
analysisLoad calculation, finite element, FMEA/FTA, PL evaluationAssumptions are explicit and worst-case operating conditions are traceable
designDrawings, BOM, pneumatic circuit/electrical diagram, software versionConsistent with analysis and reality
VerificationTest plan, original curves, photos, logsInject faults, time bases and criteria complete
Release ApprovalDeviation list, rectification closed loop, signature and maintenance requirementsUnclosed issues have clear restrictions

The test signals should use a unified time base to allow analysis of cause and effect relationships between commands, valve actions, pressure changes, locking displacements and carrier stops. Simply saving an HMI screenshot is not sufficient to support fault response verification.

07Secure recovery, maintenance and change management

Abnormal recovery shall be defined during design. Typical steps include stopping the carrier, confirming load retention, establishing temporary support, isolating energy, clearing the fault, reconfirming lock engagement, low-speed set-down, and reset approval. Personnel shall not stand beneath the battery pack or rely on continuous manual support. If a mechanical lock must be released manually, the action shall be controlled by tooling, authorization, and confirmed support conditions.

Maintenance items include latch wear, arm deformation, fasteners, hose wear, valve contamination, sensor targets, cable kinks, contact pad material and calibration status. Any changes in battery pack mass, center of gravity, shell structure, allowed support points, tooling module, software recipe or carrier acceleration should trigger impact analysis and necessary revalidation.

08Conclusions and applicable limitations

Fail-safe design of power-battery-pack handling tooling shall begin with the structural load path; pneumatic, electrical, and control systems then provide state confirmation, fault diagnostics, and controlled release. The safety objective is not to maintain cycle time after a fault, but to prevent hazardous release and bring the system to a safely recoverable state. Fault-injection verification shall correspond to the requirements, FMEA/FTA, control logic, and actual structure, forming an auditable evidence chain.

This report is an engineering research and verification plan. It is not evidence of product conformity to GB 38031, ISO 13849 performance-level certification, third-party inspection, or customer acceptance. Competent professionals shall design and approve each project in accordance with applicable regulations, standards, customer specifications, and actual risks.

References

  1. GB 38031-2025 Safety requirements for power batteries for electric vehicles. https://openstd.samr.gov.cn/bzgk/std/newGbInfo?hcno=3AB693FAFF5D9716DF61C61D6FD2187A
  2. ISO 13849-1:2023. Safety of machinery - Safety-related parts of control systems - Part 1: General principles for design. https://www.iso.org/standard/73481.html
  3. ISO 13849-2:2012. Safety of machinery - Safety-related parts of control systems - Part 2: Validation. https://www.iso.org/standard/53640.html
  4. ISO 12100:2010. Safety of machinery - General principles for design - Risk assessment and risk reduction. https://www.iso.org/standard/51528.html
  5. ISO/TR 20218-1:2018. Robotics - Safety design for industrial robot systems - Part 1: End-effectors. https://www.iso.org/standard/69488.html
  6. ISO 4414:2010. Pneumatic fluid power - General rules and safety requirements for systems and their components. https://www.iso.org/standard/44790.html
  7. ISO/TR 14121-2:2012. Safety of machinery - Risk assessment - Part 2: Practical guidance and examples of methods. https://www.iso.org/standard/57180.html
  8. U.S. Department of Transportation / NHTSA. Safety Management of Automotive Rechargeable Energy Storage Systems. https://rosap.ntl.bts.gov/view/dot/38221/dot_38221_DS1.pdf
  9. Held, M.; Bronnimann, R. Safe cell, safe battery? Battery fire investigation using FMEA, FTA and practical experiments. Microelectronics Reliability 64, 2016. https://doi.org/10.1016/j.microrel.2016.07.051
Need a car moving station plan evaluation?Please provide the workpiece weight, dimensions, on-site layout, complete movements and rhythm, and AUREK can assist in checking the equipment and fixture solutions.
View automotive industry solutions

Frequently Asked Questions · FAQ

Does fail-safe mean that the equipment continues to produce after the gas is cut off?

No. The focus of failure safety is to avoid dangerous releases and stop dangerous actions, and then resume after the load is safely placed and the fault is eliminated.

Can a gas tank replace a mechanical lock?

Usually not. Gas storage can only provide a limited holding time, and heavy-duty fixtures should preferably use geometric support and verifiable mechanical self-holding.

Can fault injection directly use real battery packs?

Model, low-energy bench and equivalent surrogate load testing should be completed first, and only necessary projects use real battery packs under risk-controlled and authorized conditions.

Does the report identify performance levels for ISO 13849?

No. The required performance level must be determined by risk assessment of the specific application, and only the design and verification methods are given in this article.

Can GB 38031 directly prove that the handling tooling is qualified?

No. GB 38031 is oriented to the safety of power battery products. The fixture still needs to be designed and verified in accordance with applicable mechanical safety standards, customer specifications and project risks.